Please note we are not a Honda dealer. Honda is a registered trademark of Honda Motor Co.
HONDA Propane Whisper
Quiet Inverter Generator
Off-Grid 4 Package
conversion by Genconnex Direct
Includes
Genconnex
®
detachable 100 or 150
foot wired start/stop exclusive for
Genconnex
®
Bi-Fuel EU7000is
START PROCEDURE:
1 - Plug in remote behind battery door
2 - Turn generator key to ‘ON” position
3 - Press remote “on button”
4 - Press remote “start” button
STOP PROCEDURE:
press remote “power” button again
$6,640.46
In Stock!
+ Shipping $599.99
Typical Configuration
240Vac well pump
Large refrigerator
Large freezer
Heating system or window A/C units
Hall or bathroom lights
Garage door opener
Microwave and coffee maker
Internet/TV and room light
kitchen light
120Vac sump pump
Accessories
More Options
A NOTE ABOUT
NATURAL GAS APPLIANCES:
Some
states
(including
but
not
limited
to
MA)
require
portable
generators
that
are
connected
to
a
home’s
gas
supply
(even
temporarily)
to
be
listed
devices.
Other
states
default
to
the
International
Fuel
Gas
Code
and
allow
non-listed
outdoor
only
devices
such
as
outdoor
natural
gas
grills,
heat
lamps
and
other
accessories
to
be
installed
as
permitted
by
your
town
and
local
inspector.
Please
check
first
with
your
local
inspector
if
you
are
not sure.
Always use a
licensed plumber!
This is your home.
Get it done right and get it
inspected. Nobody knows state,
federal and local safety codes
better than the licensed experts.
All off our generators work with our optional
APC/HONDA programmable auto load
shedding 120Vac transfer switch kits. Our kits
aren’t just the basic switch, but come complete
with an outdoor water tight power inlet install
package
This switch, designed by APC and HONDA will
automatically shed less needed loads to make sure there’s
enough power to start critical loads. Then it automatically
turns the other loads back on as more power becomes
available!
For instance, it will automatically turn off your fridge and
freezer for 10min while you make popcorn in your
microwave - even with a 2000Watt Honda or Yamaha!
This is how you connect your home to your
generator
GET A
“SMART” CIRCUIT
TRANSFER SWITCH!
Automatic
home
backup of
6-10
circuits!
Includes a 30Amp
outdoor inlet kit
Need
Automatic
Load
Management?
Add 12’ x 1/2”id quick-
disconnect extension
hose for propane and
natural gas
Add 12’ x 3/8”id
quick-disconnect
extension hose for
propane
Add 6’ x 3/8”id stainless
steel over-braided quick-
disconnect extension
hose for propane
Generator Features & Benefits
- 7,000 / 5,500 Watts peak/rated propane
- EFI Electronic fuel induction control constantly adjusts
to correct performance for optimum fuel usage
- Ultra Sound Absorbing Enclosure
At 52dBa @1/4 load, 60 dBa @ rated load
- Inverter Output
Fuel efficient and electronics safe
- Push button start or remote start
Built-in secondary safety solenoid required for remote start
- 120/240Vac or 120Vac
Selection switch on front
- Built-in Power Meter
Know what your loads each draw
- Warranty
- We offer a new limited warranty of
3 years/1000hr - see our warranty page.
- EPA certified 50 States
Add Honda Silver
EU7000is cover
Add 120/240 30Amp
to RV 50Amp trailer
adapter
Add Honda parallel kit
for paralleling two
EU7000is units together
3/8” Female
to generator
1/2” Male
to supply
12ft x 1/2” I.D. Hose
Propane Natural Gas
Load
0.94 gal/hr 84,000 BTU/hr 5500 Watts
0.52 gal/hr 46,000 BTU/hr 2750 Watts
0.37 gal/hr 32,700 BTU/hr 1375 Watts
How long will
my tank last?
Shutoff +Quick Disconnect
How simple is it?
Add an outdoor shutoff valve then a quick-
disconnect for your generator and gas grill.
Then order one of our gas extension hoses
and...
We use the same pressure as the
natural gas or propane inside your
home.
Add optional gasoline tank
with fuel pump to convert
back to gasoline in about 15
minutes!
Add Genconnex
wired
remote start/stop
Shipping Rates Apply
To lower 48 States Only
Want to pick it up at a T-Force Freight Terminal?
SHIPPING NOTES:
Not eligible for shipping to Canada
Click on pictures to enlarge
NOTE: IN CALIFORNIA FOR STATIONARY
EMERGENCY USE ONLY.
Add 25ft Extension
Cord, 10gauge, L14-30
to L14-30, 120/240Vac
7.5kWatt rated
Add Outdoor inlet box
for L14-30, 120/240Vac
7.5kWatt rated
extension cord
Add Dual Tank
Auto-Switchover
regulator with 10ft
hose & Quick
disconnect output
Add Genconnex
EU7000is
Cold Weather Kit for
natural gas and propane
operation below 0.0 deg F
How do I connect
to my home’s
natural gas or
propane?
Additional Information
NOTE: Freight may not deliver if your driveway is too steep or
not accessible by small box truck
FUEL USAGE
All Genconnex generators have a
⅜” quick disconnect inlet for easily
connecting to your grill port or BBQ
tank using our hose with pressure
reducing regulator to a pressure of
7-13”w.c., (aka 1/2” PSI)
GENERATOR DIMENSIONS
28”W x 34”L x 30”H x 254lbs
FUEL CONNECTION
4 standard GFCI outlets, 1 30Amp-
120Vac outlet and 1 30Amp-120/240
outlet under protective covers. note
to use 4 prong 120/240 outlet press
selector switch to 120/240Vac
Genconnex billet
aluminum & brass
propane and natural
gas injection system
included
1
Output ratings are +/-3% measured at 68deg F, 29.92
inches of mercury. Your results may vary at different
temperature, and air pressure/altitude
Genconnex Direct
‘Off-Grid 4’
Package ‘Off-Grid 4’
7kWatt 240Vac Propane Generator
100ft wired remote start/stop
#18 gauge
5 conductor
Direct Burial Jacket
6 pin plug
Easy to install and it won’t
drain your generator’s battery!
What’s Included
Genconnex generator
GXG-LPNG-EU7000is-WSA-EC
Custom GSCM-mini-i controller with
10’ cord and connector to plug into
front battery compartment remote port
that and can be configured for either a
closed contact start system or a
+12Vdc (Outback Inverter) start.
12 foot 3/8 propane quick-disconnect
extension hose with extra 3/8” female
quick-disconnect w/NPTpipe threads
Oil funnel and 1 quart of fully
synthetic oil
Specifications
All generators offered for sale by Genconnex Direct are intended for use as backup
generators for non-life critical applications only see our Terms and Conditions of Sale &
Use). We recommend that you consult with a engineering specialist for life-critical
backup or emergency care power applications and the use of a diesel or turbine designed
to run well over 5,000hrs - 10,000hrs between rebuilds for remote continuous power.
NOTE: KEY START OR REMOTE START ONLY